美标热轧H型钢W18*11*86型号对照表
美标型钢:SPCD——表示冲压用冷轧碳素钢薄板及钢带,相当于8AL(13237)优质碳素结构钢。SPCE——表示深冲用冷轧碳素钢薄板及钢带,相当于8AL(5213)深冲钢。需保证非时效性时,在牌号末尾加N为SPCEN。冷轧碳素钢薄板及钢带调质代号:退火状态为A,标准调质为S,1/8硬为8,1/4硬为4,1/2硬为2,硬为1。表面加工代号:无光泽精轧为D,光亮精轧为B。如SPCC-SD表示标准调质、无光泽精轧的一般用冷轧碳素薄板。
美标H型钢尺寸表:
W14*16*500 | W360*410*744 | 498*432*55.6*88.9 | 744 | W36*16.5*302 | W920*420*449 | 948*423*24*42.7 | 449 |
W14*16*550 | W360*410*818 | 514*437*60.5*97 | 818 | W36*16.5*330 | W920*420*491 | 957*422*25.9*47 | 491 |
W14*16*605 | W360*410*900 | 531*442*65.9*106 | 900 | W36*16.5*361 | W920*420*537 | 965*425*28.4*51.1 | 537 |
W14*16*665 | W360*410*990 | 550*448*71.9*115 | 990 | W36*16.5*395 | W920*420*588 | 975*427*31*55.9 | 588 |
W14*16*730 | W360*410*1086 | 569*454*78*125 | 1086 | W36*16.5*441 | W920*420*656 | 987*431*34.5*62 | 656 |
W14*16*808 | W360*410*1202 | 580*471*95*130 | 1202 | W36*16.5*487 | W920*420*725 | 999*434*38.1*68.1 | 725 |
W14*16*873 | W360*410*1299 | 600*476*100*140 | 1299 | W36*16.5*529 | W920*420*787 | 1011*437*40.9*73.9 | 787 |
W16*5.5*26 | W410*140*38.8 | 399*140*6.4*8.8 | 38.8 | W36*16.5*652 | W920*420*970 | 1043*446*50*89.9 | 970 |
W16*5.5*31 | W410*140*46.1 | 403*140*7*11.2 | 46.1 | W36*16.5*723 | W920*420*1077 | 1061*451*55*99.1 | 1077 |
W16*7*36 | W410*180*53 | 403*177*7.5*10.9 | 53 | W36*16.5*802 | W920*420*1194 | 1081*457*60.5*109 | 1194 |
W16*7*40 | W410*180*60 | 407*178*7.7*12.8 | 60 | W36*16.5*853 | W920*420*1269 | 1093*461*64*115.1 | 1269 |
W16*7*45 | W410*180*67 | 410*179*8.8*14.4 | 67 | W36*16.5*925 | W920*420*1377 | 1093*473*76.7*115.1 | 1377 |
W16*7*50 | W410*180*75 | 413*180*9.7*16 | 75 | W40*12*149 | W1000*300*222 | 970*300*16*21.1 | 222 |
W16*7*57 | W410*180*85 | 417*181*10.9*18.2 | 85 | W40*12*167 | W1000*300*249 | 980*300*16.5*26 | 249 |
W16*10.25*67 | W410*260*100 | 415*260*10*16.9 | 100 | W40*12*183 | W1000*300*272 | 990*300*16.5*31 | 272 |
W16*10.25*77 | W410*260*114 | 420*261*11.6*19.3 | 114 | W40*12*211 | W1000*300*314 | 1000*300*19.1*35.9 | 314 |
英标H型钢型号表:
W18*7.5*65 | W460*190*97 | 466*193*11.4*19 | 97 | W40*16*215 | W1000*400*321 | 990*400*16.5*31 | 321 |
W18*7.5*71 | W460*190*106 | 469*194*12.6*20.6 | 106 | W40*16*249 | W1000*400*371 | 1000*400*19*36.1 | 371 |
W18*11*76 | W460*280*113 | 463*280*10.8*17.3 | 113 | W40*16*277 | W1000*400*412 | 1008*402*21.1*40 | 412 |
W18*11*86 | W460*280*128 | 467*282*12.2*19.6 | 128 | W40*16*297 | W1000*400*443 | 1012*402*23.6*41.9 | 443 |
W18*11*97 | W460*280*144 | 472*283*13.6*22.1 | 144 | W40*16*324 | W1000*400*483 | 1020*404*25.4*46 | 483 |
W18*11*106 | W460*280*158 | 476*284*15*23.9 | 158 | W40*16*362 | W1000*400*539 | 1030*407*28.4*51.1 | 539 |
W18*11*119 | W460*280*177 | 482*286*16.6*26.9 | 177 | W40*16*372 | W1000*400*554 | 1032*408*29.5*52 | 554 |
W18*11*130 | W460*280*193 | 489*283*17*30.5 | 193 | W40*16*397 | W1000*400*591 | 1040*409*31*55.9 | 591 |
W18*11*143 | W460*280*213 | 495*285*18.5*33.5 | 213 | W40*16*431 | W1000*400*642 | 1048*412*34*60 | 642 |
W18*11*158 | W460*280*235 | 501*287*20.6*36.6 | 235 | W40*16*503 | W1000*400*748 | 1068*417*39*70 | 748 |
W18*11*175 | W460*280*260 | 509*289*22.6*40.4 | 260 | W40*16*593 | W1000*400*883 | 1092*424*45.5*82 | 883 |
W18*11*192 | W460*280*286 | 517*291*24.4*44.4 | 286 | W40*16*655 | W1000*400*976 | 1108*428*50*89.9 | 976 |
W18*11*211 | W460*280*315 | 525*293*26.9*48.5 | 315 | W44*16*230 | W1100*400*343 | 1090*400*18*31 | 343 |
W18*11*234 | W460*280*349 | 535*296*29.5*53.6 | 349 | W44*16*262 | W1100*400*390 | 1100*400*20*36 | 390 |
W18*11*258 | W460*280*384 | 545*299*32.5*58.4 | 384 | W44*16*290 | W1100*400*433 | 1108*402*22*40 | 433 |
W18*11*283 | W460*280*421 | 555*302*35.6*63.5 | 421 | W44*16*335 | W1100*400*499 | 1118*405*26*45 | 499 |
W18*11*311 | W460*280*464 | 567*305*38.6*69.6 | 464 | W44*16*368 | W1100*400*548 | 1128*407*28*50 | 548 |
W44*16*408 | W1100*400*607 | 1138*410*31*55 | 607 |
英标型材:
与此相反,如果热力膨胀阀开启过大,即热力膨胀阀向蒸发器的供液量大于蒸发器负荷,会造成部分制冷剂来不及在蒸发器内蒸发,同气态制冷剂一起进入压缩机,引起湿冲程,甚至冲缸事故,损坏压缩机。年,杭州市电信分公司景芳二楼程控机房有一台ISOPAK机房专用空调的一个压缩机阀片被击穿,可能与热力膨胀阀开启过大有关;同时,热力膨胀阀开启过大,使蒸发温度升高,制冷量下降,压缩机功耗增加,增加了耗电量。有必要定期检查调整热力膨胀阀,尽量让热力膨胀阀工作在匹配点。力膨胀阀的调整过程4.1热力膨胀阀调整前的检查在调整热力膨胀阀之前,必须确认空调制冷异常是由于热力膨胀阀偏离工作点引起的,而不是因为氟利昂少、干燥过滤器堵塞、滤网、风机、皮带等其他原因所引起的。同时,必须保证感温包采样信号的正确性,机房专用空调的感温包必须水平安装在回气管的下侧方45度的位置,不可安装在管道的正下方,以防管子底部积油等因素影响感温包正确感温。更不能安装在立管上。检查冷凝器风机控制方式,尽量采用调速控制,以保证冷凝压力恒定。2热力膨胀阀调整时注意事项热力膨胀阀的调整工作,必须在制冷装置正常运行状态下进行。由于蒸发器表面无法放置测温计,可以利用压缩机的吸气压力作为蒸发器内的饱和压力,查表得到近似蒸发温度。用测温计测出回气管的温度,与蒸发温度对比来校核过热度。调整中,如果感到过热度太小,则可把调节螺杆按顺时针方向转动(即增大弹簧力,减小热力膨胀阀开启度),使流量减小;反之,若感到过热度太大,即供液不足,则可把调节螺杆朝相反方向(逆时针)转动,使流量增大。